登录进入交换机后,执行show log,会看到如下的提示:
21w6d: %ETHCNTR-3-LOOP_BACK_DETECTED: Keepalive packet loop-back detected on FastEthernet0/20.
21w6d: %PM-4-ERR_DISABLE: loopback error detected on Fa0/20, putting Fa0/20 in err-disable state
以上信息就明确表示由于检测到第20端口出现了环路,所以将该端口置于了err-disable状态。
查看端口的状态
Switch# show inter fa0/20 status
Port Name Status Vlan Duplex Speed Type
Fa0/20 link to databackup err-disabled 562 auto auto 10/100BaseTX
这条信息更加明确的表示了该端口处于err-disabled状态。
既然看到了该端口是被置于了错误的状态了,我们就应该有办法将其再恢复成正常的状态。
拯救步骤2:将端口从错误状态中恢复回来
进入交换机全局配置模式,执行errdisable recovery cause ?,会看到如下信息:
Switch(config)#errdisable recovery cause ?
all Enable timer to recover from all causes
bpduguard Enable timer to recover from BPDU Guard error disable state
channel-misconfig Enable timer to recover from channel misconfig disable state
dhcp-rate-limit Enable timer to recover from dhcp-rate-limit error disable state
dtp-flap Enable timer to recover from dtp-flap error disable state
gbic-invalid Enable timer to recover from invalid GBIC error disable state
l2ptguard Enable timer to recover from l2protocol-tunnel error disable state
link-flap Enable timer to recover from link-flap error disable state
loopback Enable timer to recover from loopback detected disable state
pagp-flap Enable timer to recover from pagp-flap error disable state
psecure-violation Enable timer to recover from psecure violation disable state
security-violation Enable timer to recover from 802.1x violation disable state
udld Enable timer to recover from udld error disable state
unicast-flood Enable timer to recover from unicast flood disable state
vmps Enable timer to recover from vmps shutdown error disable state